Tags | Dieser Datensatz ist Bestandteil der ÖKOBAUDAT. |
Key Data Set Information | |
Location | DE |
Reference year | 2016 |
Name |
|
Use advice for data set | Scope: This document is valid for the following FPO synthetic roofing and waterproofing sheet systems: · BauderTHERMOPLAN T (12/15/16/18/20) · BauderTHERMOPLAN T (15/18/20) V manufactured in the German BAUDER production plant in Schwepnitz. This document is translated from the German Environmental Product Declaration into English. It is based on the German original version EPD-BAU-20160222-IBC1-DE. The verifier has no influence on the quality of the translation. System boundary: Type of EPD: cradle to plant gate (with options) The following modules are used in accordance with EN 15804: Module A1-3 All upstream chains associated with the raw materials used and procurement transport thereof Production processes including energy and waste flows (cradle to plant gate) Waste incurred is considered until it reaches End of Waste status. Module A4-5 Transport to the construction site and average installation effort (hot air-welding and cuttings incurred) Recycling the packaging material Fastening material is not a component of the product system under review. Reference should be made to the respective EPD in line with the product or material used (metal/plastic). Module C2-1 Transport within the framework of the recycling route Module C2-2 Transport within the framework of the incineration route Module C3-1 Material utilisation (recycling) of the product including processing effort Module C3-2 Thermal utilisation (incineration in an incineration plant) to reduce the volume of waste for landfilling Modules D-1 and D-2 Credits arising from waste treatment in Modules A5, C3-1 and C3-2 |
Technical purpose of product or process | FPO roofing and waterproofing sheets are applied in single layers and hot air-welded at the seams. They are safeguarded against wind suction by mechanical fastening, ballasting or adhesion. Roof waterproofing: single-layer waterproofing of flat and inclined used and unused roofs Building waterproofing: single-layer waterproofing of non-waterproof buildings and components against ground damp and non-pressurised water Depending on the respective requirements, BauderTHERMOPLAN roofing and waterproofing sheets are: · fastened mechanically, · laid under load or · adhered. Application rules Directive (EU) No. 305/2011 applies for placing the product on the market in the EU/EFTA (with the exception of Switzerland). The products require a Declaration of Performance taking consideration of the harmonised /EN 13956/ and /EN 13967/ specifications and CE marking. Use in Germany is governed by the respective national regulations. For roofing sheets Application standard /DIN V 20000-201/: BauderTHERMOPLAN T 12/15/16/18/20 DE/E1 FPO-BV-V-PG-1.2 (1.5/1.6/1.8/2.0) BauderTHERMOPLAN T 15/18/20 V DE/E1 FPO-BV-V-PG-K-KV- 1.5 (1.8/2.0) For waterproofing sheets Application standard /DIN V 20000-202/: BauderTHERMOPLAN T 12/15/16/18/20 BA FPO-BV-V-PG-1.2 (1.5/1.6/1.8/2.0) BauderTHERMOPLAN T 15/18/20 V BA FPO-BV-V-PG-K-KV- 1.5 (1.8/2.0) |
Classification number | 6.3.03 |
Classification |
Class name
:
Hierarchy level
|
General comment on data set | BauderTHERMOPLAN are FPO-based synthetic roofing and waterproofing sheets reinforced with synthetic fibres. The product range comprises the following variants: |
Scenarios |
|
Copyright | Yes |
Owner of data set | |
Quantitative reference | |
Reference flow(s) |
|
Time representativeness | |
Data set valid until | 2021 |
Technological representativeness | |
Technology description including background system | FPO roofing and waterproofing sheets are manufactured in a single-stage process. The raw materials for the upper and lower layers are blended and plasticised separately on the extruders. The polyester fabric reinforcement is coated with the lower foil layer first, then the upper foil layer. Some FPO roofing and waterproofing sheets feature special fleece lamination on the underside. After cooling and final edge trimming, the products are packed. All production waste incurred is recycled and redirected to the manufacturing process. Declared unit: The declared unit is 1 m² average THERMOPLAN FPO roofing and waterproofing sheet T (12/15/16/18/20) and T (15/18/20) V variants, mechanically fastened or fastened under load, sealed using hot air, including packaging materials. |
Flow diagram(s) or picture(s) |
Subtype | average dataset | ||||
LCA methodology report |
| ||||
Data sources, treatment and representativeness | |||||
Documentation of data quality management |
| ||||
Data source(s) used for this data set |
| ||||
Completeness | |||||
Validation | |||||
| |||||
Compliance Declarations |
Compliance |
Compliance system name
|
Approval of overall compliance
|
Nomenclature compliance
|
Methodological compliance
|
Review compliance
|
Documentation compliance
|
Quality compliance
|
Compliance |
Compliance system name
ISO 14025
|
Approval of overall compliance
|
Nomenclature compliance
|
Methodological compliance
|
Review compliance
|
Documentation compliance
|
Quality compliance
|
Data entry by | |
Time stamp (last saved) | 2016-10-04T14:57:11.208 |
Data set format(s) | |
Data entry by | |
Publication and ownership | |
UUID | 9179f12a-8fef-4319-a150-a6bb1286c37c |
Data set version | 00.05.000 |
Owner of data set | |
Copyright | Yes |
Indicators of life cycle